Omega Engineering FP-6000 Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
Important Safety Information!
CAUTION:
(Standard version) Never remove the flow sensor
from a pressurized pipe. Always wear safety face
protection during sensor installation/removal.
(Hot-Tap version) Follow the recommended
installation/removal instructions in this manual.
Always wear safety face protection during sensor
installation/removal.
Maximum Operating Pressure:
225 psi (15 bar)
Maximum Operating Temperature:
212 °F (100 °C)
Serious bodily injury and/or damage to the sensor
can result if the conditions and specifications
presented in this manual are exceeded. DO NOT
exceed specifications under any circumstances.
Pipe fittings MUST be installed by a certified
welder only. OMEGA will not assume liability of
any kind for improper fitting installations.
The FP-6000 Hot-Tap system's overall specifica-
tions and limitations depend on the lowest maxi-
mum rating of the components associated with the
system. In other words, the Hot-Tap system is only
as strong as its weakest link. For example, a ball
valve, a component of the system, is rated at a
maximum 100 psi @ 185 °F, limiting the entire
system's maximum pressure/temperature rating to
100 psi @ 185 °F. All higher maximum specifica-
tions MUST yield to the component with the lowest
maximum specification.
Seitenansicht 4
1 2 3 4 5 6 7 8 9 10 ... 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare