FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Seite 2

pg. 10 of 29 c) Electrical Connections – Voltage Output Units The cable assembly should be connected to the sensor as detailed in section 5(b) above

Seite 3

pg. 11 of 29 d) Using a 0-5VDC Output Power Adapter Package. An optional 0-5VDC Output Power Adapter Package is available for use with the FLR 1000

Seite 4 - Introduction

pg. 12 of 29 C. Operation CAUTION: DO NOT FLOW ANY LIQUID THROUGH A GAS FLOW SENSOR OR FLOW METER. THIS WILL SERIOUSLY EFFECT THE PERFORMANCE AND VO

Seite 5 - Installation

pg. 13 of 29 100-500 ml/min and in l/min for flow ranges of 0.2 – 1.0 L/min and above. The display will only operate if power is applied to the unit.

Seite 6 - Mounting The Sensor

pg. 14 of 29 4. Zero Adjustments It is impossible for there to be any zero drift so zero adjustments are never required. 5. Recalibration Please

Seite 7

pg. 15 of 29 If the unit has a flow reading of 200ml/min then the corrected flow reading (for CO2) would be: Corrected Flow = 200 X 0.88 = 176 ml/mi

Seite 8

pg. 16 of 29 D. Maintenance and Product Care 1. General CAUTION: Do not disassemble your unit for any reason. If the unit appears to be malfuncti

Seite 9

pg. 17 of 29 E. Specifications For Gas Units FLR1000 FLR1000-D FLR1000-BR-D Display None 3.5 Digit LCD, 0.39” (10mm) high digits Accuracy (inclu

Seite 10

pg. 18 of 29 F. Connector Pin And Wire Color Cross Reference Pin Configuration for Connector Socket and Connector Pin Cable Wire Color D

Seite 11

pg. 19 of 29 G. Dimensions ALL DIMENSIONS IN INCHES (MILLIMETERS IN BRACKETS) FLR 1000 For Gases 20-200 ml/min To 1.0-5.0 l/min Units 1/4” Acetal

Seite 13 - LCD Flow Display

pg. 20 of 29 FLR 1000 For Gases 2.0-10.0 l/min Units 1/4” Acetal Fittings Shown

Seite 14

pg. 21 of 29 FLR 1000 For Gases 4.0-20.0 l/min To 100-500 l/min Units 1/2” Acetal Fittings Shown

Seite 15

pg. 22 of 29 FLR 1000-D For Gases 20-200 ml/min To 1.0-5.0 l/min Units 1/4” Acetal Fittings Shown

Seite 16 - Maintenance and Product Care

pg. 23 of 29 FLR 1000-D For Gases 2.0-10.0 l/min Units 1/4” Acetal Fittings Shown

Seite 17 - Specifications For Gas Units

pg. 24 of 29 FLR 1000-D For Gases 4.0-20.0 l/min To 100-500 l/min Units 1/2” Acetal Fittings Shown

Seite 18

pg. 25 of 29 FLR 1000-BR-D For Gases 20-200 ml/min To 1.0-5.0 l/min Units 1/4” Brass Fittings Shown

Seite 19 - Dimensions

pg. 26 of 29 H. Troubleshooting Guide Symptom Possible Cause Method of Correction Unit Leaks Fittings not tight enough. Sensor assembly cracked

Seite 20 - 1/4” Acetal Fittings Shown

pg. 27 of 29 Symptom Possible Cause Method of Correction Flow indication is not linear and output too low at lower flows Attempting to measure flow

Seite 22 - FLR 1000-D For Gases

M4575/0807 pg. 29 of 29

Seite 23

pg. 3 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY RESULT IN INJURY TO YOU OR D

Seite 24

pg. 4 of 29 A. Introduction 1. Unpacking All units are suitably packaged to prevent damage during shipping. If external damage is noted upon rece

Seite 25 - 1/4” Brass Fittings Shown

pg. 5 of 29 proven design minimizes zero drift while maintaining fast response and linear outputs with virtually no maintenance. Flow is measured u

Seite 26 - Troubleshooting Guide

pg. 6 of 29 1. General Considerations It is recommended that a safety shut-off valve be installed upstream of (before) the sensor. All wetted part

Seite 27

pg. 7 of 29 3. Tubing Connections CAUTION: DO NOT FLOW ANY LIQUID THROUGH A GAS FLOW SENSOR OR FLOW METER. THIS WILL SERIOUSLY EFFECT THE PERFORMAN

Seite 28

pg. 8 of 29 Close Up of Label Showing Flow Direction (FLR 1000 shown, other models similar) The tubing ID should be as large as possible to avoid r

Seite 29 - M4575/0807 pg. 29 of 29